dc.description.abstractE-rehabilitation is the term used to define medical rehabilitation programs that are implemented at home with the use of information and communication technologies. The aim was to test whether sensor position and the sitting position of the patient influence the accuracy of knee range of movement (ROM) data displayed by the BPMpathway e-rehabilitation system. A preliminary study was conducted in a laboratory setting with healthy adults. Knee ROM data was measured with the BPMpathway e-rehabilitation system and simultaneously with a BIOPAC twin-axis digital goniometer. The main outcome was the root mean squared error (RMSE). A 20% increase or reduction in sitting height led to a RMSE increase. A ventral shift of the BPMpathway sensor by 45◦ and 90◦ caused significant measurement errors. A vertical shift was associated with a diminution of the measurement errors. The lowest RMSE (2.4◦) was achieved when the sensor was placed below the knee. The knee ROM data measured by the BPMpathway system is comparable to the data of the concurrent system, provided the instructions of the manufacturer are respected concerning the sitting position of the subject for knee exercises, and disregarding the same instructions for sensor positioning, by placing the sensor directly below the knee.en
dc.language.isoenen_US
dc.publisherMDPIen_US
dc.relation.ispartofSensorsen_US
dc.subjectE-Healthen_US
dc.subjectKneeen_US
dc.subjectPhysiotherapyen_US
dc.subjectRange of movementen_US
dc.subjectTelerehabilitationen_US
dc.subjectTotal knee arthroplastyen_US
dc.subjectValidityen_US
dc.subject.ddc610: Medizinen_US
dc.titleSensor positioning influences the accuracy of knee rom data of an e-rehabilitation system : a preliminary study with healthy subjectsen
dc.typeArticleen_US
dc.description.versionPeerRevieweden_US
tuhh.container.issue8en_US
tuhh.container.volume20en_US
tuhh.oai.showtrueen_US
tuhh.publication.instituteFakultät Life Sciencesen_US
tuhh.publication.instituteDepartment Medizintechniken_US
tuhh.publication.instituteDepartment Gesundheitswissenschaftenen_US
tuhh.publisher.doi10.3390/s20082237-
tuhh.type.opus(wissenschaftlicher) Artikel-
dc.rights.cchttps://creativecommons.org/licenses/by/4.0/en_US
dc.type.casraiJournal Article-
dc.type.diniarticle-
dc.type.driverarticle-
dc.type.statusinfo:eu-repo/semantics/publishedVersionen_US
dcterms.DCMITypeText-
tuhh.container.articlenumber2237-
item.openairecristypehttp://purl.org/coar/resource_type/c_6501-
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.openairetypeArticle-
item.creatorGNDMarques, Carlos J.-
item.creatorGNDBauer, Christian-
item.creatorGNDGrimaldo, Dafne-
item.creatorGNDTabeling, Steffen Otto Josef Alfons-
item.creatorGNDWeber, Timo-
item.creatorGNDEhlert, Alexander-
item.creatorGNDMendes, Alexandre H.-
item.creatorGNDLorenz, Jürgen-
item.creatorGNDLampe, Frank-
item.languageiso639-1en-
item.creatorOrcidMarques, Carlos J.-
item.creatorOrcidBauer, Christian-
item.creatorOrcidGrimaldo, Dafne-
item.creatorOrcidTabeling, Steffen Otto Josef Alfons-
item.creatorOrcidWeber, Timo-
item.creatorOrcidEhlert, Alexander-
item.creatorOrcidMendes, Alexandre H.-
item.creatorOrcidLorenz, Jürgen-
item.creatorOrcidLampe, Frank-
item.cerifentitytypePublications-
crisitem.author.deptDepartment Gesundheitswissenschaften-
crisitem.author.deptDepartment Medizintechnik-
crisitem.author.deptDepartment Medizintechnik-
crisitem.author.parentorgFakultät Life Sciences-
crisitem.author.parentorgFakultät Life Sciences-
crisitem.author.parentorgFakultät Life Sciences-
Enthalten in den Sammlungen:Publications without full text
Zur Kurzanzeige

Seitenansichten

10
checked on 06.07.2024

Google ScholarTM

Prüfe

HAW Katalog

Prüfe

Volltext ergänzen

Feedback zu diesem Datensatz


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons