DC ElementWertSprache
dc.contributor.authorHahne, Janne Mathias-
dc.contributor.authorWilke, Meike A.-
dc.contributor.authorKoppe, Mario-
dc.contributor.authorFarina, Dario-
dc.contributor.authorSchilling, Arndt F.-
dc.date.accessioned2024-03-25T11:09:39Z-
dc.date.available2024-03-25T11:09:39Z-
dc.date.issued2020-06-17-
dc.identifier.issn1662-453Xen_US
dc.identifier.urihttp://hdl.handle.net/20.500.12738/15311-
dc.description.abstractHand prostheses are usually controlled by electromyographic (EMG) signals from the remnant muscles of the residual limb. Most prostheses used today are controlled with very simple techniques using only two EMG electrodes that allow to control a single prosthetic function at a time only. Recently, modern prosthesis controllers based on EMG classification, have become clinically available, which allow to directly access more functions, but still in a sequential manner only. We have recently shown in laboratory tests that a regression-based mapping from EMG signals into prosthetic control commands allows for a simultaneous activation of two functions and an independent control of their velocities with high reliability. Here we aimed to study how such regression-based control performs in daily life in a two-month case study. The performance is evaluated in functional tests and with a questionnaire at the beginning and the end of this phase and compared with the participant’s own prosthesis, controlled with a classical approach. Already 1 day after training of the regression model, the participant with transradial amputation outperformed the performance achieved with his own Michelangelo hand in two out of three functional metrics. No retraining of the model was required during the entire study duration. During the use of the system at home, the performance improved further and outperformed the conventional control in all three metrics. This study demonstrates that the high fidelity of linear regression-based prosthesis control is not restricted to a laboratory environment, but can be transferred to daily use.en
dc.language.isoenen_US
dc.publisherFrontiersen_US
dc.relation.ispartofFrontiers in neuroscienceen_US
dc.subjectMyolectric controlen_US
dc.subjectprosthesisen_US
dc.subjectregressionen_US
dc.subjectsimultaneous controlen_US
dc.subjectclinical evaluationen_US
dc.subject.ddc610: Medizinen_US
dc.titleLongitudinal case study of regression-based Hand Prosthesis Control in Daily Lifeen
dc.typeArticleen_US
dc.description.versionPeerRevieweden_US
local.contributorPerson.editorContreras-Vidal, Jose Luis-
tuhh.container.volume14en_US
tuhh.oai.showtrueen_US
tuhh.publication.instituteDepartment Biotechnologieen_US
tuhh.publication.instituteFakultät Life Sciencesen_US
tuhh.publisher.doi10.3389/fnins.2020.00600-
tuhh.type.opus(wissenschaftlicher) Artikel-
dc.rights.cchttps://creativecommons.org/licenses/by/4.0/en_US
dc.type.casraiJournal Article-
dc.type.diniarticle-
dc.type.driverarticle-
dc.type.statusinfo:eu-repo/semantics/publishedVersionen_US
dcterms.DCMITypeText-
local.comment.externalarticle number: 600en_US
item.openairecristypehttp://purl.org/coar/resource_type/c_6501-
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.openairetypeArticle-
item.creatorGNDHahne, Janne Mathias-
item.creatorGNDWilke, Meike A.-
item.creatorGNDKoppe, Mario-
item.creatorGNDFarina, Dario-
item.creatorGNDSchilling, Arndt F.-
item.languageiso639-1en-
item.creatorOrcidHahne, Janne Mathias-
item.creatorOrcidWilke, Meike A.-
item.creatorOrcidKoppe, Mario-
item.creatorOrcidFarina, Dario-
item.creatorOrcidSchilling, Arndt F.-
item.cerifentitytypePublications-
crisitem.author.deptDepartment Biotechnologie-
crisitem.author.orcid0000-0003-0329-8407-
crisitem.author.parentorgFakultät Life Sciences-
Enthalten in den Sammlungen:Publications without full text
Zur Kurzanzeige

Seitenansichten

8
checked on 04.07.2024

Google ScholarTM

Prüfe

HAW Katalog

Prüfe

Volltext ergänzen

Feedback zu diesem Datensatz


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons