Publisher DOI: 10.1109/JSEN.2022.3213868
Title: A multichannel EMG system for spatial measurement of diaphragm activities
Language: English
Authors: Kusche, Roman  
Graßhoff, Jan 
Oltmann, Andra 
Rostalski, Philipp 
Keywords: diaphragmatic electromyography (EMGdi); Dry electrodes; electrical activity of the diaphragm (EAdi); electrode belt; electromyography; measurement system; multichannel; respiration monitoring; spatiotemporal electromyography (EMG)
Issue Date: 18-Oct-2022
Publisher: IEEE
Journal or Series Name: IEEE sensors journal 
Volume: 22
Issue: 23
Startpage: 23393
Endpage: 23402
Abstract: 
An important aspect of mechanical ventilation is the recognition and quantification of spontaneous respiratory effort. However, a measurement of flows and pressures often used for this purpose is prone to error. A promising alternative is to detect diaphragmatic contractions, directly. A method recently proposed is to acquire the diaphragm electromyography (EMG) signals using surface electrodes. However, this method is often limited by disturbances and electrode placements for some applications in which the patient is moving, such as rehabilitation or breathing training. In this work, we present a novel noninvasive method that addresses these problems. This method is based on a novel dry electrode belt, which can be used to comfortably derive EMG signals from the thorax, in combination with a developed electrical measurement system. The modular multichannel system is capable of simultaneously deriving and digitizing 32 differential EMG channels and sending them to a personal computer (PC). A specific digital signal processing chain allows combining the data into one robust overall signal. In addition, the signals derived from the thorax can be used to obtain information regarding the spatiotemporal propagation of the diaphragm EMG. To verify the functionality, the system is characterized. Subsequently, subject measurements are performed. From these, the spatiotemporal propagation of diaphragm EMG on the thorax can be identified. For better visualization, this propagation is graphically displayed in a 3-D model. In addition, it is shown how the combination of all signals can be used to obtain a robust overall signal that can be used to control ventilators.
URI: http://hdl.handle.net/20.500.12738/15547
ISSN: 1558-1748
Review status: This version was peer reviewed (peer review)
Institute: Fraunhofer-Einrichtung für Individualisierte und Zellbasierte Medizintechnik 
Type: Article
Appears in Collections:Publications without full text

Show full item record

Page view(s)

82
checked on Nov 23, 2024

Google ScholarTM

Check

HAW Katalog

Check

Add Files to Item

Note about this record


This item is licensed under a Creative Commons License Creative Commons