DC FieldValueLanguage
dc.contributor.authorGiewekemeyer, Klaus-
dc.contributor.authorHackenberg, Claudia-
dc.contributor.authorAquila, Andrew-
dc.contributor.authorWilke, Robin Niklas-
dc.contributor.authorGroves, Matthew R.-
dc.contributor.authorJordanova, Rositsa-
dc.contributor.authorLamzin, Victor S.-
dc.contributor.authorBorchers, Gannon-
dc.contributor.authorSaksl, Karel-
dc.contributor.authorZozulya, Alexey V.-
dc.contributor.authorSprung, Michael-
dc.contributor.authorMancuso, Adrian P.-
dc.date.accessioned2024-04-23T09:36:13Z-
dc.date.available2024-04-23T09:36:13Z-
dc.date.issued2015-11-03-
dc.identifier.issn1542-0086en_US
dc.identifier.urihttp://hdl.handle.net/20.500.12738/15592-
dc.description.abstractThe structural investigation of noncrystalline, soft biological matter using x-rays is of rapidly increasing interest. Large-scale x-ray sources, such as synchrotrons and x-ray free electron lasers, are becoming ever brighter and make the study of such weakly scattering materials more feasible. Variants of coherent diffractive imaging (CDI) are particularly attractive, as the absence of an objective lens between sample and detector ensures that no x-ray photons scattered by a sample are lost in a limited-efficiency imaging system. Furthermore, the reconstructed complex image contains quantitative density information, most directly accessible through its phase, which is proportional to the projected electron density of the sample. If applied in three dimensions, CDI can thus recover the sample's electron density distribution. As the extension to three dimensions is accompanied by a considerable dose applied to the sample, cryogenic cooling is necessary to optimize the structural preservation of a unique sample in the beam. This, however, imposes considerable technical challenges on the experimental realization. Here, we show a route toward the solution of these challenges using ptychographic CDI (PCDI), a scanning variant of coherent imaging. We present an experimental demonstration of the combination of three-dimensional structure determination through PCDI with a cryogenically cooled biological sample—a budding yeast cell (Saccharomyces cerevisiae)—using hard (7.9 keV) synchrotron x-rays. This proof-of-principle demonstration in particular illustrates the potential of PCDI for highly sensitive, quantitative three-dimensional density determination of cryogenically cooled, hydrated, and unstained biological matter and paves the way to future studies of unique, nonreproducible biological cells at higher resolution.en
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.relation.ispartofBiophysical journal : BJen_US
dc.subject.ddc570: Biowissenschaften, Biologieen_US
dc.titleTomography of a cryo-immobilized yeast cell using ptychographic coherent X-Ray diffractive imagingen
dc.typeArticleen_US
dc.description.versionPeerRevieweden_US
tuhh.container.endpage1995en_US
tuhh.container.issue9en_US
tuhh.container.startpage1986en_US
tuhh.container.volume109en_US
tuhh.oai.showtrueen_US
tuhh.publication.instituteGeorg-August-Universität Göttingenen_US
tuhh.publisher.doi10.1016/j.bpj.2015.08.047-
tuhh.type.opus(wissenschaftlicher) Artikel-
dc.rights.cchttps://creativecommons.org/licenses/by-nc-nd/4.0/en_US
dc.type.casraiJournal Article-
dc.type.diniarticle-
dc.type.driverarticle-
dc.type.statusinfo:eu-repo/semantics/publishedVersionen_US
dcterms.DCMITypeText-
item.creatorOrcidGiewekemeyer, Klaus-
item.creatorOrcidHackenberg, Claudia-
item.creatorOrcidAquila, Andrew-
item.creatorOrcidWilke, Robin Niklas-
item.creatorOrcidGroves, Matthew R.-
item.creatorOrcidJordanova, Rositsa-
item.creatorOrcidLamzin, Victor S.-
item.creatorOrcidBorchers, Gannon-
item.creatorOrcidSaksl, Karel-
item.creatorOrcidZozulya, Alexey V.-
item.creatorOrcidSprung, Michael-
item.creatorOrcidMancuso, Adrian P.-
item.grantfulltextnone-
item.fulltextNo Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_6501-
item.openairetypeArticle-
item.creatorGNDGiewekemeyer, Klaus-
item.creatorGNDHackenberg, Claudia-
item.creatorGNDAquila, Andrew-
item.creatorGNDWilke, Robin Niklas-
item.creatorGNDGroves, Matthew R.-
item.creatorGNDJordanova, Rositsa-
item.creatorGNDLamzin, Victor S.-
item.creatorGNDBorchers, Gannon-
item.creatorGNDSaksl, Karel-
item.creatorGNDZozulya, Alexey V.-
item.creatorGNDSprung, Michael-
item.creatorGNDMancuso, Adrian P.-
item.languageiso639-1en-
item.cerifentitytypePublications-
crisitem.author.deptDepartment Maschinenbau und Produktion-
crisitem.author.orcid0000-0002-9263-1904-
crisitem.author.parentorgFakultät Technik und Informatik-
Appears in Collections:Publications without full text
Show simple item record

Page view(s)

6
checked on May 17, 2024

Google ScholarTM

Check

HAW Katalog

Check

Add Files to Item

Note about this record


This item is licensed under a Creative Commons License Creative Commons