Verlagslink DOI: 10.1007/s00330-019-06362-x
Titel: Towards clinical grating-interferometry mammography
Sprache: Englisch
Autorenschaft: Arboleda, Carolina 
Wang, Zhentian 
Jefimovs, Konstantins 
Köhler, Thomas 
van Stevendaal, Udo 
Kuhn, Norbert 
David, Bernd 
Prevrhal, Sven 
Lång, Kristina 
Forte, Serafino 
Kubik-Huch, Rahel Antonia 
Leo, Cornelia 
Singer, Gad 
Marcon, Magda 
Boss, Andreas 
Roessl, Ewald 
Stampanoni, Marco 
Schlagwörter: Interferometry; Mammography; Phase contrast; Breast
Erscheinungsdatum: 22-Aug-2019
Verlag: Springer
Zeitschrift oder Schriftenreihe: European radiology 
Zeitschriftenband: 30
Zeitschriftenausgabe: 3
Anfangsseite: 1419
Endseite: 1425
Zusammenfassung: 
Objectives: Grating-interferometry-based mammography (GIM) might facilitate breast cancer detection, as several research works have demonstrated in a pre-clinical setting, since it is able to provide attenuation, differential phase contrast, and scattering images simultaneously. In order to translate this technique to the clinics, it has to be adapted to cover a large field-of-view within a clinically acceptable exposure time and radiation dose. Methods: We set up a grating interferometer that fits into a standard mammography system and fulfilled the aforementioned conditions. Here, we present the first mastectomy images acquired with this experimental device. Results and conclusion: Our system performs at a mean glandular dose of 1.6 mGy for a 5-cm-thick, 18%-dense breast, and a field-of-view of 26 × 21 cm2. It seems to be well-suited as basis for a clinical-environment device. Further, dark-field signals seem to support an improved lesion visualization. Evidently, the effective impact of such indications must be evaluated and quantified within the context of a proper reader study. Key Points: • Grating-interferometry-based mammography (GIM) might facilitate breast cancer detection, since it is sensitive to refraction and scattering and thus provides additional tissue information. • The most straightforward way to do grating-interferometry in the clinics is to modify a standard mammography device. • In a first approximation, the doses given with this technique seem to be similar to those of conventional mammography.
URI: https://hdl.handle.net/20.500.12738/16285
ISSN: 1432-1084
Begutachtungsstatus: Diese Version hat ein Peer-Review-Verfahren durchlaufen (Peer Review)
Einrichtung: Fakultät Life Sciences 
Department Medizintechnik 
Dokumenttyp: Zeitschriftenbeitrag
Enthalten in den Sammlungen:Publications without full text