| Verlagslink DOI: | 10.1109/PerComWorkshops68308.2026.11585248 10.48550/arXiv.2510.26501 |
Titel: | Enhancing ECG classification robustness with lightweight unsupervised anomaly detection filters | Sprache: | Englisch | Autorenschaft: | Ibrahim, Mustafa Fuat Rifet Meijer, Maurice Schlaefer, Alexander Stelldinger, Peer |
Schlagwörter: | Machine Learning; continuous patient monitoring; ecg analysis; unsupervised anomaly detection; out-of-distribution detection; open set recognition; wearable devices | Erscheinungsdatum: | 2026 | Verlag: | IEEE | Teil der Schriftenreihe: | 2026 IEEE International Conference on Pervasive Computing and Communications Workshops and other Affiliated Events (PerCom Workshops) | Konferenz: | IEEE International Conference on Pervasive Computing and Communications Workshops and other Affiliated Events (PerCom Workshops) 2026 | Zusammenfassung: | Continuous electrocardiogram (ECG) monitoring via wearable devices is vital for early cardiovascular disease detection. However, deploying deep learning models on resource-constrained microcontrollers faces reliability challenges, particularly from Out-of-Distribution (OOD) pathologies and noise. Standard classifiers often yield high-confidence errors on such data. Existing OOD detection methods either neglect computational constraints or address noise and unseen classes separately. This paper investigates Unsupervised Anomaly Detection (UAD) as a lightweight, upstream filtering mechanism. We perform a Neural Architecture Search (NAS) on six UAD approaches, including Deep Support Vector Data Description (Deep SVDD), input reconstruction with (Variational-)Autoencoders (AE/VAE), Masked Anomaly Detection (MAD), Normalizing Flows (NFs) and Denoising Diffusion Probabilistic Models (DDPM) under strict hardware constraints ( ≤512k parameters), suitable for microcontrollers. Evaluating on the PTB-XL and BUT QDB datasets, we demonstrate that a NAS-optimized Deep SVDD offers the superior Pareto efficiency between detection performance and model size. In a simulated deployment, this lightweight filter improves the accuracy of a diagnostic classifier by up to 21.0 percentage points, demonstrating that optimized UAD filters can safeguard ECG analysis on wearables. |
URI: | https://hdl.handle.net/20.500.12738/19350 | ISBN: | 979-8-3315-7615-8 979-8-3315-7616-5 |
ISSN: | 2766-8576 | Begutachtungsstatus: | Diese Version hat ein Peer-Review-Verfahren durchlaufen (Peer Review) | Einrichtung: | Competence Center Smart Systems in Society Fakultät Informatik und Digitale Gesellschaft |
Dokumenttyp: | Konferenzveröffentlichung | Hinweise zur Quelle: | Preprint: https://doi.org/10.48550/arXiv.2510.26501. Verlagsversion: https://doi.org/10.1109/PerComWorkshops68308.2026.11585248. |
| Enthalten in den Sammlungen: | Publications without full text |
Zur Langanzeige
Volltext ergänzen
Feedback zu diesem Datensatz
Export
Alle Ressourcen in diesem Repository sind urheberrechtlich geschützt.