Fulltext available Open Access
DC FieldValueLanguage
dc.contributor.advisorAndrä, Jörg-
dc.contributor.authorHeim, Marie Christin-
dc.date.accessioned2026-11-10T15:19:33Z-
dc.date.available2026-11-10T15:19:33Z-
dc.date.issued2026-08-04-
dc.identifier.urihttps://hdl.handle.net/20.500.12738/20328-
dc.description.abstractThe invention of X-ray free-electron lasers revolutionised the field of time-resolved crystallography by utilising the ultrashort X-ray pulses to probe reactions down to the femtosecond timescale, permitting unprecedented insights into the dynamics of biological processes. At the European X-ray Free-Electron Laser, the megahertz repetition rate and high peak brilliance enable the collection of multiple time points within a single experiment at a high spatio-temporal resolution. However, beamtime is highly limited and requires extensive preparatory work and additional data-processing steps compared to traditional crystallography. In this study, the preparatory work and data analysis are represented by analysing two distinct systems that both aim to enhance experiments performed at the Single Particles, Clusters, and Biomolecules & Serial Femtosecond Crystallography instrument at the European XFEL facility. Initial experiments on thymine dimerisation in DNA oligomers to validate the instrumental set-up for pump-probed experiments involved UV irradiation, subsequent testing for structural changes, as well as crystallisation and collection of diffraction data at a synchrotron source. The analysis of time-resolved serial femtosecond crystallography diffraction data was performed as part of an experiment on the applicability of an oxygen photocage by processing the diffraction patterns and refining the structures. While leakage from the photocage led to premature oxygenation of the test molecule, which could not be sufficiently compensated by a reduced contact time, the DNA reporter system showed structural changes upon UV irradiation in the initial tests and, with further improvement, could be implemented as a validation system improving the efficient use of beamtime.en
dc.language.isoenen_US
dc.subjectCrystallographyen_US
dc.subjectX-rayen_US
dc.subjectfree-electron laseren_US
dc.subjectbiological processesen_US
dc.subject.ddc500: Naturwissenschaftenen_US
dc.subject.ddc570: Biowissenschaften, Biologieen_US
dc.titleIlluminated in Time : Evaluating a Reporter System and a Molecular Cage for Time- Resolved Serial Femtosecond X-ray Crystallography at the European X-ray Free- Electron Laseren
dc.typeThesisen_US
openaire.rightsinfo:eu-repo/semantics/openAccessen_US
thesis.grantor.departmentFakultät Life Sciencesen_US
thesis.grantor.universityOrInstitutionHochschule für Angewandte Wissenschaften Hamburgen_US
tuhh.contributor.refereeBean, Richard-
tuhh.identifier.urnurn:nbn:de:gbv:18302-reposit-250010-
tuhh.oai.showtrueen_US
tuhh.publication.instituteFakultät Life Sciencesen_US
tuhh.type.opusMasterarbeit-
dc.type.casraiSupervised Student Publication-
dc.type.dinimasterThesis-
dc.type.drivermasterThesis-
dc.type.statusinfo:eu-repo/semantics/publishedVersionen_US
dc.type.thesismasterThesisen_US
dcterms.DCMITypeText-
tuhh.dnb.statusdomainen_US
item.openairecristypehttp://purl.org/coar/resource_type/c_46ec-
item.creatorOrcidHeim, Marie Christin-
item.fulltextWith Fulltext-
item.advisorGNDAndrä, Jörg-
item.languageiso639-1en-
item.openairetypeThesis-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.creatorGNDHeim, Marie Christin-
Appears in Collections:Theses
Files in This Item:
Show simple item record

Google ScholarTM

Check

HAW Katalog

Check

Note about this record


Items in REPOSIT are protected by copyright, with all rights reserved, unless otherwise indicated.