| Title: | Energy Demand Comparison of Passive, Naturally Ventilated and Earth Air Heat Exchanger (EAHE) integrated Double Skin Facade (DSF) Design Strategies for an Existing Building in Hamburg : A TRNSYS and TRNFlow Simulation Study | Language: | English | Authors: | Eckhof, Lisa | Keywords: | Earth Air Heat Exchanger; Energy Demand Comparison; renewable technologie; Double Skin Facade; thermal buffer | Issue Date: | 6-Apr-2026 | Abstract: | Improving the envelope of existing building’s is critical for reducing heating demand and enabling renewable technologies, particularly in the context of building’s accounting for 34% of global CO2 emissions worldwide in 2023 [1, p.13]. Installing a Double Skin Facade (DSF) as an extended outer envelope in front of a building creates a thermal buffer zone, which reduces the building’s heating demand but is also prone to overheating in summer. Although this overheating problem is addressed in research through different ventilation strategies and shading devices, integrated passive design strategies implementing Earth Air Heat Exchanger (EAHE) remain largely unexplored. Therefore, this thesis investigates an alternative design combining EAHE with DSF in Hamburg’s moderate climate conditions. The passive strategy consists of 20 pipes, each 30 m long, 0.25m diameter, buried at a depth of 2 m and preconditioning the air entering the DSF cavity. By precooling air in summer and preheating the air in winter, the EAHE is expected to reduce overheating in summer and enhance the thermal buffer effect in winter, although the latter is not the focus of this research. The central research question is whether this integrated design can outperform a traditional naturally ventilated DSF with ventilation openings at the cavity’s bottom and top (Open Air Curtain (OAC)) in reducing overheating inside the building. To answer this question, the dynamic thermal simulation software TRNSYS and its airflow component TRNFlow are utilized to simulate the following model variations: (1) building without DSF, (2) building with DSF (with open or closed ventilation openings), and (3) building with DSF and EAHE (1-20 pipes). The building model represents a multifamily building from 1921 in Hamburg, using TRY 2045 climate data to simulate expected warmer temperatures due to climate change. The results show that the integrated EAHE design outperforms the OAC design beginning at 14 pipes. At the maximum configuration of 20 pipes, the integrated design achieves 707 h/a, which is a 9.4% reduction compared to the OAC design and an 11.4% reduction compared to the building without DSF (798 h/a). The OAC design achieves a reduction in overheating hours to approximately the level of the building without DSF (798 h/a), while the integrated design provides moderate additional improvement. Although the EAHE precools the inlet air, solar radiation raises the temperature within DSF cavity, which limits the overall cooling benefit of the EAHA system compared to the OAC design. Despite the moderate improvement, the system demonstrates that inlet air temperature has a significant impact on the cooling performance of the system compared to the OAC design, achieving comparable performance at significantly lower airflow rates. System optimizations through sensitivity analysis show that increasing burial depth to 2.5m achieves the greatest performance improvement (637 h/a), which is 18.3% better than the OAC design, while increasing pipe length to 40m provides diminishing returns (695 h/a). However, a significant finding is that directing EAHE precooled air directly into the building achieves 573 h/a, representing a 26.5% improvement compared to the OAC design. This demonstrates the systems potential and shows that solar heating within the DSF cavity is the primary limiting factor of the integrated system. Major limitations of this study include indirect airflow coupling between building and DSF, which prevents the evaluation of absolute performance values, the deactivation of the EAHE during winter due to TRNSYS convergence issues (inability to evaluate EAHE winter heating benefits), and the lack of experimental validation. |
URI: | https://hdl.handle.net/20.500.12738/20384 | Institute: | Fakultät Life Sciences | Type: | Thesis | Thesis type: | Bachelor Thesis | Advisor: | Schäfers, Hans | Referee: | Schwerdtfeger, Sarah |
| Appears in Collections: | Theses |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| BA_Energy Demand Comparison of Passive, Naturally Ventilated and Earth Air Heat Exchanger_geschwärzt.pdf | 3.28 MB | Adobe PDF | View/Open |
Note about this record
Export
Items in REPOSIT are protected by copyright, with all rights reserved, unless otherwise indicated.