Volltextdatei(en) in REPOSIT vorhanden Open Access
DC ElementWertSprache
dc.contributor.advisorUeberle, Friedrich-
dc.contributor.authorHahn, Christoph
dc.date.accessioned2020-09-29T11:40:34Z-
dc.date.available2020-09-29T11:40:34Z-
dc.date.created2012
dc.date.issued2012-08-31
dc.identifier.urihttp://hdl.handle.net/20.500.12738/5909-
dc.description.abstractTranscranial Direct Current Stimulation (tDCS) is a non-invasive brain stimulation technique aiming to polarize brain tissue in order to elicit modulating effects on cortical activity. During tDCS, weak constant current is applied across the brain through surface electrodes which are attached to the scalp. tDCS has shown promising therapeutic effects in a range of neurological conditions and is being evaluated for therapeutic use in epilepsy, major depression, chronic pain, stroke rehabilitation and more. Though tDCS is a generally well tolerated treatment option, there is room for improvement of patient safety and comfort. During tDCS, current is constant and skin-electrode impedance is strongly dynamic. Thus, compliance voltage is also dynamic. Skin-electrode impedance may be influenced through choice of electrode type and the way of electrode preparation prior to treatment. High impedance and voltage during tDCS can co-induce skin burns at the electrode sites. Here, feasibility of reduced (peak) voltage tDCS is investigated and presented alongside a rather protective and advanced new approach for voltage and current control during tDCS. According to the results, the maximum stimulator output voltage may be reduced significantly in the most common tDCS paradigms without affecting stimulation intensity and efficacy. Optimized electrode preparation combined with reduced maximum stimulator output voltage and intelligent current waveforms is considered a viable contribution towards more safe, protective and reliable brain stimulation paradigms, especially avoiding the occurrence of skin lesions after multiple stimulation treatments.en
dc.language.isoenen
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/-
dc.subjecttDCSen
dc.subjecttranscraniel direct current stimulationen
dc.subject.ddc610 Medizin, Gesundheit
dc.titleExtra-Low Voltage and Limited Total Energy Approaches to Increase Patient Comfort and Safety During Transcranial Direct Current Stimulationen
dc.typeThesis
openaire.rightsinfo:eu-repo/semantics/openAccess
thesis.grantor.departmentDepartment Medizintechnik
thesis.grantor.placeHamburg
thesis.grantor.universityOrInstitutionHochschule für angewandte Wissenschaften Hamburg
tuhh.contributor.refereeBikson, Marom-
tuhh.gvk.ppn723434301
tuhh.identifier.urnurn:nbn:de:gbv:18302-reposit-59114-
tuhh.note.externpubl-mit-pod
tuhh.note.intern1
tuhh.oai.showtrueen_US
tuhh.opus.id1832
tuhh.publication.instituteDepartment Medizintechnik
tuhh.type.opusBachelor Thesis-
dc.subject.gndElektrostimulation
dc.subject.gndGehirn
dc.type.casraiSupervised Student Publication-
dc.type.dinibachelorThesis-
dc.type.driverbachelorThesis-
dc.type.statusinfo:eu-repo/semantics/publishedVersion
dc.type.thesisbachelorThesis
dcterms.DCMITypeText-
tuhh.dnb.statusdomain-
item.creatorGNDHahn, Christoph-
item.fulltextWith Fulltext-
item.creatorOrcidHahn, Christoph-
item.grantfulltextopen-
item.cerifentitytypePublications-
item.advisorGNDUeberle, Friedrich-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_46ec-
item.openairetypeThesis-
Enthalten in den Sammlungen:Theses
Dateien zu dieser Ressource:
Datei GrößeFormat
lsab12_86.pdf1.4 MBAdobe PDFÖffnen/Anzeigen
Zur Kurzanzeige

Seitenansichten

156
checked on 27.12.2024

Download(s)

58
checked on 27.12.2024

Google ScholarTM

Prüfe

HAW Katalog

Prüfe

Feedback zu diesem Datensatz


Alle Ressourcen in diesem Repository sind urheberrechtlich geschützt.