DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Ueberle, Friedrich | - |
dc.contributor.author | Ortiz Reyes, Rosa Elena | |
dc.date.accessioned | 2020-09-29T15:05:09Z | - |
dc.date.available | 2020-09-29T15:05:09Z | - |
dc.date.created | 2017 | |
dc.date.issued | 2019-05-07 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12738/8728 | - |
dc.description.abstract | Objective: Recent studies have proven a dependency between MRI relaxation times (T2 , T2) and blood oxygen saturation levels (sO2) applying blood oxygenation level dependent (BOLD) sequences [24, 27, 49]. With this approach, the present work focuses on measuring the T2 dependency on fetal sO2 at 3T MRI in-vitro and quantifying its relationship. Thereafter this quanti cation would be applied to in-vivo fetal imaging to develop a non-invasive method that measures sO2 based on signal intensities. Method: T2 measurements were performed on a 3T MRI scanner using a T2 preparation pulse and a balanced- SSFP sequence. Calibration experiments where made using MnCl2 phantoms and hole blood samples retrieved from the umbilical cord. Signal intensities where tted by a monoexponential equation to calculate T2 values, and a quadratic model was applied to determine the oxygen dependency. Afterwards, signal intensities in the fetal left ventricle where obtained in-vivo and correlated with the in-vitro calibration. Results: The resulting quantitative correlation equation used for calculating fetal oxygenation in-vivo is R2 = 0:0041+0:058(1 | en |
dc.language.iso | en | en |
dc.rights.uri | http://rightsstatements.org/vocab/InC/1.0/ | - |
dc.subject.ddc | 610 Medizin, Gesundheit | |
dc.title | Simulation and Measurement of Fetal Blood Oxygen Saturation based on T2 Values at 3T MRI | en |
dc.type | Thesis | |
openaire.rights | info:eu-repo/semantics/openAccess | |
thesis.grantor.department | Department Medizintechnik | |
thesis.grantor.place | Hamburg | |
thesis.grantor.universityOrInstitution | Hochschule für angewandte Wissenschaften Hamburg | |
tuhh.contributor.referee | Ruprecht, Christian | - |
tuhh.gvk.ppn | 1665041587 | |
tuhh.identifier.urn | urn:nbn:de:gbv:18302-reposit-87306 | - |
tuhh.note.extern | publ-mit-pod | |
tuhh.note.intern | 1 | |
tuhh.oai.show | true | en_US |
tuhh.opus.id | 4792 | |
tuhh.publication.institute | Department Medizintechnik | |
tuhh.type.opus | Masterarbeit | - |
dc.subject.gnd | Fetus | |
dc.subject.gnd | Simulation | |
dc.subject.gnd | Messung | |
dc.subject.gnd | Sauerstoffsättigung | |
dc.subject.gnd | Kernspintomografie | |
dc.type.casrai | Supervised Student Publication | - |
dc.type.dini | masterThesis | - |
dc.type.driver | masterThesis | - |
dc.type.status | info:eu-repo/semantics/publishedVersion | |
dc.type.thesis | masterThesis | |
dcterms.DCMIType | Text | - |
tuhh.dnb.status | domain | - |
item.advisorGND | Ueberle, Friedrich | - |
item.languageiso639-1 | en | - |
item.fulltext | With Fulltext | - |
item.creatorGND | Ortiz Reyes, Rosa Elena | - |
item.openairetype | Thesis | - |
item.grantfulltext | open | - |
item.creatorOrcid | Ortiz Reyes, Rosa Elena | - |
item.cerifentitytype | Publications | - |
item.openairecristype | http://purl.org/coar/resource_type/c_46ec | - |
Appears in Collections: | Theses |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
1._RosaElena_OrtizReyes_2247279.pdf | 11.08 MB | Adobe PDF | View/Open |
Note about this record
Export
Items in REPOSIT are protected by copyright, with all rights reserved, unless otherwise indicated.