Fulltext available Open Access
DC FieldValueLanguage
dc.contributor.advisorUeberle, Friedrich-
dc.contributor.authorOrtiz Reyes, Rosa Elena
dc.date.accessioned2020-09-29T15:05:09Z-
dc.date.available2020-09-29T15:05:09Z-
dc.date.created2017
dc.date.issued2019-05-07
dc.identifier.urihttp://hdl.handle.net/20.500.12738/8728-
dc.description.abstractObjective: Recent studies have proven a dependency between MRI relaxation times (T2 , T2) and blood oxygen saturation levels (sO2) applying blood oxygenation level dependent (BOLD) sequences [24, 27, 49]. With this approach, the present work focuses on measuring the T2 dependency on fetal sO2 at 3T MRI in-vitro and quantifying its relationship. Thereafter this quanti cation would be applied to in-vivo fetal imaging to develop a non-invasive method that measures sO2 based on signal intensities. Method: T2 measurements were performed on a 3T MRI scanner using a T2 preparation pulse and a balanced- SSFP sequence. Calibration experiments where made using MnCl2 phantoms and hole blood samples retrieved from the umbilical cord. Signal intensities where tted by a monoexponential equation to calculate T2 values, and a quadratic model was applied to determine the oxygen dependency. Afterwards, signal intensities in the fetal left ventricle where obtained in-vivo and correlated with the in-vitro calibration. Results: The resulting quantitative correlation equation used for calculating fetal oxygenation in-vivo is R2 = 0:0041+0:058(1en
dc.language.isoenen
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/-
dc.subject.ddc610 Medizin, Gesundheit
dc.titleSimulation and Measurement of Fetal Blood Oxygen Saturation based on T2 Values at 3T MRIen
dc.typeThesis
openaire.rightsinfo:eu-repo/semantics/openAccess
thesis.grantor.departmentDepartment Medizintechnik
thesis.grantor.placeHamburg
thesis.grantor.universityOrInstitutionHochschule für angewandte Wissenschaften Hamburg
tuhh.contributor.refereeRuprecht, Christian-
tuhh.gvk.ppn1665041587
tuhh.identifier.urnurn:nbn:de:gbv:18302-reposit-87306-
tuhh.note.externpubl-mit-pod
tuhh.note.intern1
tuhh.oai.showtrueen_US
tuhh.opus.id4792
tuhh.publication.instituteDepartment Medizintechnik
tuhh.type.opusMasterarbeit-
dc.subject.gndFetus
dc.subject.gndSimulation
dc.subject.gndMessung
dc.subject.gndSauerstoffsättigung
dc.subject.gndKernspintomografie
dc.type.casraiSupervised Student Publication-
dc.type.dinimasterThesis-
dc.type.drivermasterThesis-
dc.type.statusinfo:eu-repo/semantics/publishedVersion
dc.type.thesismasterThesis
dcterms.DCMITypeText-
tuhh.dnb.statusdomain-
item.advisorGNDUeberle, Friedrich-
item.languageiso639-1en-
item.fulltextWith Fulltext-
item.creatorGNDOrtiz Reyes, Rosa Elena-
item.openairetypeThesis-
item.grantfulltextopen-
item.creatorOrcidOrtiz Reyes, Rosa Elena-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_46ec-
Appears in Collections:Theses
Files in This Item:
File Description SizeFormat
1._RosaElena_OrtizReyes_2247279.pdf11.08 MBAdobe PDFView/Open
Show simple item record

Page view(s)

118
checked on Jan 13, 2025

Download(s)

128
checked on Jan 13, 2025

Google ScholarTM

Check

HAW Katalog

Check

Note about this record


Items in REPOSIT are protected by copyright, with all rights reserved, unless otherwise indicated.