Fulltext available Open Access
DC FieldValueLanguage
dc.contributor.advisorBishop, Nicholas-
dc.contributor.authorSteffens, Florian
dc.date.accessioned2020-09-29T15:30:02Z-
dc.date.available2020-09-29T15:30:02Z-
dc.date.created2019
dc.date.issued2019-09-27
dc.identifier.urihttp://hdl.handle.net/20.500.12738/9110-
dc.description.abstractThe chronical obstructive pulmonary disease (COPD) is allready one of the leading deadly diseases and numbers are rising. Smoking is one of the main causes of COPD. The disease is not curable, a treatment only relieves symptoms. In severe cases, the a ected su er from hypoxemia and thus lose quality of life which results in a downwards spirale. If a patient‘s state is severe and stable, treating with long term oxygen therapy is possible but to stay mobile, the patient needs a mobile oxygen device. There are many devices which all di er from each other. The aim of this bachelorthesis is to examine how distinct the di ernces betweeen eight pulse dose oxygen concentrators and two liquid oxygen devices are. At rst, a demand oxygen test system is used to measure while applying two di erent breathing frequencies. Afterwards, the method of cost–utility analysis is used rating the ten devices. It was found that even the same device type di ers a lot at the same pulse dose setting. Furthermore, the technical aimed cost-utility analysis revealed three favourites. More research is needed, especially focusing on the paramters of pulse dose delivery systems. The exact factors are still unclear.en
dc.language.isodede
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/-
dc.subject.ddc610 Medizin, Gesundheit
dc.titleVergleichsstudie mobiler und tragbarer Sauersto konzentratorende
dc.typeThesis
openaire.rightsinfo:eu-repo/semantics/openAccess
thesis.grantor.departmentDepartment Medizintechnik
thesis.grantor.placeHamburg
thesis.grantor.universityOrInstitutionHochschule für angewandte Wissenschaften Hamburg
tuhh.contributor.refereeWernicke, Annika-
tuhh.gvk.ppn1677848235
tuhh.identifier.urnurn:nbn:de:gbv:18302-reposit-91120-
tuhh.note.externpubl-mit-pod
tuhh.note.intern1
tuhh.oai.showtrueen_US
tuhh.opus.id5192
tuhh.publication.instituteDepartment Medizintechnik
tuhh.type.opusBachelor Thesis-
dc.subject.gndVergleich
dc.subject.gndStudie
dc.subject.gndSauerstoffkonzentrator
dc.type.casraiSupervised Student Publication-
dc.type.dinibachelorThesis-
dc.type.driverbachelorThesis-
dc.type.statusinfo:eu-repo/semantics/publishedVersion
dc.type.thesisbachelorThesis
dcterms.DCMITypeText-
tuhh.dnb.statusdomain-
item.creatorGNDSteffens, Florian-
item.fulltextWith Fulltext-
item.creatorOrcidSteffens, Florian-
item.grantfulltextopen-
item.cerifentitytypePublications-
item.advisorGNDBishop, Nicholas-
item.languageiso639-1de-
item.openairecristypehttp://purl.org/coar/resource_type/c_46ec-
item.openairetypeThesis-
Appears in Collections:Theses
Files in This Item:
File Description SizeFormat
SteffensFlorian_geschwaerzt.pdf2.86 MBAdobe PDFView/Open
Show simple item record

Page view(s)

157
checked on Dec 27, 2024

Download(s)

617
checked on Dec 27, 2024

Google ScholarTM

Check

HAW Katalog

Check

Note about this record


Items in REPOSIT are protected by copyright, with all rights reserved, unless otherwise indicated.