Fulltext available Open Access
DC FieldValueLanguage
dc.contributor.advisorVaupel, Gustav-
dc.contributor.authorHasnain, Iffat
dc.date.accessioned2020-09-29T15:16:40Z-
dc.date.available2020-09-29T15:16:40Z-
dc.date.created2008
dc.date.issued2008-04-23
dc.identifier.urihttp://hdl.handle.net/20.500.12738/8914-
dc.description.abstractThis thesis focuses on the design, modeling and implementation of system that can simulate the resulting load profile for any required day, season etc; by using the de-tailed device parameters of building(s) in network(s) i.e. valid working time, minimum run & maximum shut down times etc, and compare the results with power consump-tion data, while being synchronized with the load management system at the same time. In this regard a work forecast algorithm was designeddeveloped which can cal-culate the possible reduction in power by turning off the devices in the remaining quarter of an hour during their valid working times; by keeping the track of device pa-rameters, hence providing the detailed information that which devices could be turned on or off and for how long. Implementation & Validation of work is done in Mat-lab/Simulink.en
dc.description.abstractDiese Arbeit konzentriert sich auf die Planung, Modellierung und Implementierung von System, dass die daraus resultierende Belastung des Profils für irgend einen gewünschten Tag, Jahreszeit etc. simulieren kann. Dazu benutzt er den de-tailed Geräteparameter der Gebäuden in den Netzwerken, d.h. gültige Arbeitszeit, Minimum & Maximum Ausschaltzeit etc, und vergleicht die Ergebnisse mit Strom-Verbrauch-Daten und ist dabei synchron mit der Last-Management-System zur gleichen Zeit. In diesem Zusammenhang wurde ein Energie Prognose Algorithmus entworfen entwickelt, die die mögliche Reduzierung der Energie durch das Ausschalten der Geräte in der verbleibenden Viertelstunde während ihres gültigen Arbeitszeiten berechnen kann, indem sie den Geräteparameter verfolgt. Kurzgefaßt, der Algorithmus stellt detaillierten Informationen bereit, welche Geräte ein-oder ausgeschaltet werden können und für wie lange. Implementierung & Validierung der Arbeit erfolgt in Mat-Lab/Simulink.de
dc.language.isoenen
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/-
dc.subject.ddc004 Informatik
dc.titleModeling the Load Pattern of a Network of Buildings with Installed Load Manage-ment Devices using Matlab/Simulink.en
dc.typeThesis
openaire.rightsinfo:eu-repo/semantics/openAccess
thesis.grantor.departmentDepartment Informatik
thesis.grantor.placeHamburg
thesis.grantor.universityOrInstitutionHochschule für angewandte Wissenschaften Hamburg
tuhh.contributor.refereeSchubert, Franz-
tuhh.gvk.ppn562821910
tuhh.identifier.urnurn:nbn:de:gbv:18302-reposit-89160-
tuhh.note.externpubl-mit-pod
tuhh.note.intern1
tuhh.oai.showtrueen_US
tuhh.opus.id501
tuhh.publication.instituteDepartment Informatik
tuhh.type.opusBachelor Thesis-
dc.subject.gndSIMULINK
dc.subject.gndMATLAB
dc.type.casraiSupervised Student Publication-
dc.type.dinibachelorThesis-
dc.type.driverbachelorThesis-
dc.type.statusinfo:eu-repo/semantics/publishedVersion
dc.type.thesisbachelorThesis
dcterms.DCMITypeText-
tuhh.dnb.statusdomain-
item.advisorGNDVaupel, Gustav-
item.languageiso639-1en-
item.fulltextWith Fulltext-
item.creatorGNDHasnain, Iffat-
item.openairetypeThesis-
item.grantfulltextopen-
item.creatorOrcidHasnain, Iffat-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_46ec-
Appears in Collections:Theses
Files in This Item:
File Description SizeFormat
Final_Report_Hasnain_Thesis.pdf1.95 MBAdobe PDFView/Open
Show simple item record

Page view(s)

187
checked on Jan 14, 2025

Download(s)

66
checked on Jan 14, 2025

Google ScholarTM

Check

HAW Katalog

Check

Note about this record


Items in REPOSIT are protected by copyright, with all rights reserved, unless otherwise indicated.